Neutrik NL2MP 2 pole chassis connector, black D-size flange, countersunk thru holes, 3/16" flat tabs. Does not intermate with the 4-pole cable connector... Electrical Specifications:... Rated current/contact: 30 A rms continous, 40 A rms 1min. Dielectric strength: 4kV peak Rated voltage: 250 V ac Contact resistance...
Neutrik NL2MP 2 pole chassis connector, black D-size flange, countersunk thru holes, 3/16" flat tabs. Does not intermate with the 4-pole cable connector.
Electrical Specifications:
Rated current/contact: 30 A rms continous, 40 A rms 1min. Dielectric strength: 4kV peak Rated voltage: 250 V ac Contact resistance: = 3 m after 5000 insertion-withdrawal operations Insulation resistance, initial: > 2 G Ohm, after damp heat test: > 1 G Ohm Inrush/outrush current capability (12 V source): 300/30 A/200 ms Creepage distance: according to IEC 664-1 Mechanical Specifications:
Lifetime: >5000 mating cycles Retention method: Quicklock with latch Cable anchoring: NEUTRIK® chuck principle Cable O.D. range: 6 - 10 mm Cable retention force: = 220 N Subject to cable die and material Wiring: screw-type terminals or soldering, 12 AWG stranded/solid Solderability complies with IEC 68-2-20 Material Specifications:
Contacts: Female: CuZn39Pb3 Securing element: ZnAI4Cu1, CuNi plated Housing: PA 6 30% GR Insert (FC part): PBTP 20% GR Bushing: PA 6 15% GR Chuck: POM Temperature range: -30°C to +80°C Flammability: UL94V-0 (housing), UL94HB Cable Wiring:
Power ("PA) Standard: a two-conductor cable for each channel with NL2FC on both ends